Specifications/Absolute Maximum Ratings (Ta=25°C)

Type

Dimensional Outline/ Window material*

Package

Cooling

Active area
(mm)

Absolute maximum ratings

Supply voltage
(V)

Operating temperature
(°C)

Storage temperature
(°C)

P9217

Drawing 1/ K

TO-5

Non- cooled

1 x 5

100

-30 to +65

-30 to +65

P9217-02

Drawing 1/ K

2 x 2

P9217-03

Drawing 1/ K

3 x 3

P9217-04

Drawing 2/ K

TO-8

4 x 5

* Window material K: Borosilicate glass


Electrical and optical characteristics

(Typ. unless otherwise noted)

Type

Peak sensitivity wavelength, lp

(µm)

Cut-off wavelength, lc

(µm)

Photo- sensitivity*

Vs =15 V

D*
(500,600, 1)

D* (l peak,600, 1)

(cm-Hz1/2/W)

Rise time
0 to 63%
(µs)

Dark resistance
MOhm

Min
(V/W)

Typ.
(V/W)

Min
(cm-Hz1/2/W)

Typ.
(cm-Hz1/2/W)

P9217

2.2

2.9

4 x 104

1 x 105

5 x 108

1 x 109

1 x 1011

200

0.05 to 1

P9217-02

5 x 104

0.25 to 2.5

P9217-03

2 x 104

5 x 104

P9217-04

1 x 104

3 x 104

2 x 108

5 x 108

5 x 1010

0.2 to 2.0

* Chopping frequency: 600Hz, load resistance: nearly equal to detector element dark resistance.


P9217/-01/-02

P-9217 Drawing 1

P9217-04

P-9217 Drawing 1

Ordering Information

P9217

 PbS photoconductive detector with 1mm x 5mm active area in TO-5 housing.

P9217-02

 PbS photoconductive detector with 2mm x 2mm active area in TO-5 housing.

P9217-03

 PbS photoconductive detector with 3mm x 3mm active area in TO-5 housing.

P9217-04

 PbS photoconductive detector with 4mm x 5mm active area in TO-8 housing.

Useful Documents

pdf

P9217 Series datasheet - pdf (66K)